Usage of totaly enclosed fan-cooled induction motors in ventilator drives /
Usage of totally encIosed fan-cooled motors in ventilator drives can be problematic because a ventilator drive usually changes the normal air flow along the motor's cooling surface, thus influencing the cooling of the driving motor. A thermal image of a totally encIosed fan-cooled two-speed thr...
Shranjeno v:
Main Authors: | , , , |
---|---|
Format: | Book Chapter |
Jezik: | English |
Teme: | |
Sorodne knjige/članki: | Vsebovano v:
Proceedings |
Oznake: |
Označite
Brez oznak, prvi označite!
|
Izvleček: | Usage of totally encIosed fan-cooled motors in ventilator drives can be problematic because a ventilator drive usually changes the normal air flow along the motor's cooling surface, thus influencing the cooling of the driving motor. A thermal image of a totally encIosed fan-cooled two-speed threephase induction motor is studied based on results from motor temperature rise tests in a ventilator drive and in a laboratory drive Presented results show that the ventilator drive affects the motor' s cooling air flow and therefore weakens the motor's cooling, especially when operating at lower speed. |
---|---|
Opis knjige/članka: | Soavtorji: Miralem Hadžiselimović, Ivan Zagradišnik, Matej Gajzer. |
Fizični opis: | Str. 157-158. |
Bibliografija: | Bibliografija: str. 158. Abstract. |
ISBN: | 839213401X |