Greatly improved small inductance measurement using quartz crystal parasitic capacitance compensation /

Generally, quartz crystal inductance frequency pulling in oscillators is very low and therefore is not often used in practice. The new method of improving frequencypullability uses inductance to compensate for quartz stray capacitances. To this end, a special AT fundamental quartz crystal working ne...

Popoln opis

Shranjeno v:
Bibliografske podrobnosti
Main Authors: Matko, Vojko. (Author), Jezernik, Karel. (Author)
Format: Book Chapter
Jezik:English
Teme:
Sorodne knjige/članki:Vsebovano v: Sensors
Oznake: Označite
Brez oznak, prvi označite!
Opis
Izvleček:Generally, quartz crystal inductance frequency pulling in oscillators is very low and therefore is not often used in practice. The new method of improving frequencypullability uses inductance to compensate for quartz stray capacitances. To this end, a special AT fundamental quartz crystal working near the antiresonance frequency is selected. By modifying its equivalent circuit with load inductance and series tuning capacitance, the magnetic sensing of the circuit can be highly improved. The experimental results show that the new approach using the quartz crystal stray capacitance compensation method increases the frequency pulling range by x 300 depending on the type of oscillator, making possible the measurement of nano-magnetic changes.
Fizični opis:str. 3954-3960.
Bibliografija:Bibliografija: str. 3959-3960.
Abstract.
ISSN:1424-8220